Comtech EF Data SLM-5650A Installation And Operation Manual page 237

Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
Number of
N/A
NUE?
Unread stored
Events
Number of
N/A
NUS?
Unread stored
Statistics
BERT Pattern
PAT=
PAT?
CnC PSD Ratio
N/A
PSD?
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
3 bytes
Query only.
Returns the Number of stored Events, which remain Unread, in the
form xxx.
Note: This means unread over the remote control.
Example: >0001/NUE=126{CR}{LF}
3 bytes
Query only.
Returns the Number of stored Statistics, which remain Unread, in the
form xxx.
Note: This means unread over the remote control.
Example: >0001/NUS=135{CR}{LF}
1 byte
Command or Query.
Sets or returns the BERT Pattern in the form x, where:
0 = 2047
1 = Mark
2 = Space
3 = 1:1
4 = 1:2
5 = 2^15-1
6 = 2^20-1
7 = 2^23-1
8 = MIL-188
Example: <0001/PAT=0{CR} (sets 2047 Pattern)
5 bytes
Query only.
When CnC is enabled and locked, returns the PSD ratio, in dB,
between the interferer and the desired signal power, in 0.1 dB steps.
Reporting format varies as follows:
Example 1: >0001/CPR=+02.8{CR}{LF} (interferer > desired)
(form=sdd.d, where: s = sign (+ / –), dd.d = value in dB)
Example 2: >0001/CPR=999.9{CR}{LF} (not locked or CnC not
enabled)
Description of Arguments
10–43
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
N/A
NUE=xxx
N/A
NUS=xxx
PAT=
PAT=x
PAT?
PAT*
PAT#
N/A
PSD=xxxxx
MN-SLM-5650A

Advertisement

Table of Contents
loading

Table of Contents