Comtech EF Data SLM-5650A Installation And Operation Manual page 229

Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

Controller-to-Target
Instruction Code and
Qualifier
Parameter
Type
Command
Query
Circuit ID String CID=
CID?
CnC Mode
CNM=
CNM?
Carrier Only
COM=
COM?
Test Modes
CnC Power
N/A
CPR?
Ratio Monitor
Serial Remote Control
Arguments
for Command
(Note that all arguments are ASCII numeric codes from 48 to 57)
or Query
24 bytes
Command or Query.
Sets or returns the user-defined Circuit ID string, where:
x = a fixed length of 24 characters.
Note: Valid characters include Space ( ) * + – , . / 0 9 and A thru Z
1 byte
Command or Query.
Sets or returns CnC Mode of Operation in the form x, where:
0 = Off
1 = On
Example: <0001/CNM=0{CR}
1 byte
Command or Query.
Sets or returns Test Mode in the form x, where:
0 = Normal Mode (no test)
1 = Tx CW
2 = Tx Alternating 1,0 Pattern
Example: <0001/COM=1{CR} (CW Mode)
6 bytes
Query only.
When CnC is enabled and locked, returns the ratio, in 0.1 dB steps,
between the interferer and the desired signal power. Reporting format
varies as follows:
Example 1: >0001/CPR=+02.8{CR}{LF} (interferer > desired)
(form=sdd.d, where: s = sign (+/–), dd.d = value in 0.1 dB steps)
Example 2: >0001/CPR=LT10.0{CR}{LF} (less than –10.0 dB)
Example 3: >0001/CPR=GT10.0{CR}{LF} (greater than +10.0 dB)
Example 4: >0001/CPR=9999.9{CR}{LF} (not locked or CnC not
enabled)
Description of Arguments
10–35
SLM-5650A Satellite Modem
Revision 10
Target-to-Controller
Response to Query
Response to
(see Description of
Command
Arguments)
CID=
CID=x
CID?
CID*
CID#
CNM=
CNM=x
CNM?
CNM*
CNM#
COM=
COM=x
COM?
COM*
COM#
N/A
CPR=xxxxxx
MN-SLM-5650A

Advertisement

Table of Contents
loading

Table of Contents