• When the temperature changed after a previous adjustment by more than a set value. The default
value is "5°C". You can adjust the temperature change value with SP 2153 12.
• When the magnification changed after a previous adjustment by more than a set value. The default
value is "1%". You can adjust the magnification change value with SP 2153 15.
Interrupt
If SP 2153 5 is set to "1 (Yes)", then the adjustment is done when the one of the following conditions occurs
during a print job with many pages.
• When the number of printed pages after the previous adjustment becomes more than a set number.
The number of pages includes black and color printing. The default value is 190 pages. (If this
condition occurs, automatic line position adjustment after the next interval process control will not be
cancelled.) You can adjust the default value with SP 2153 10.
• When the temperature changed after a previous adjustment by more than a set value. The default
value is "5°C". You can adjust the temperature change value with SP 2153 12.
• When the magnification changed after a previous adjustment by more than a set value. The default
value is "1%". You can adjust the magnification change value with SP 2153 15.
Summary Table
The below table shows when the automatic line position adjustment is done. It also shows the main SPs that
control the timing of the adjustment. If SP 2153 1 is "Off", then the automatic adjustment is never done.
Note that the adjustments for the sub-scan line position, main scan line position, and magnification are
done at the same time.
Enabled/
After Process
Disabled (SP
Control
2153
(SP 2153 2)
1)
ON
On
Off
Initialization
Printing
(SP 2153
(SP 2153
3)
4)
ON
On
Off
ON
Off
Off
On
ON
Laser Exposure
Interrupt
(SP 2153
Remarks
5)
On
Default
Off
On
Off
On
Off
On
Off
On
6
373