These SPs adjust the AC/I bias of the drum charge roller. These are used only when
SP3-501-001 is set to "1".
2203 001
RS: [K]
2203 002
RS: [M]
2203 003
RS: [C]
2203 004
RS: [Y]
[Charge Bias] Charge Roller Voltage: Corrections for humidity
(Environmental correction, [Color])
2204
For more about the humidity conditions, see SP 2304.
Adds these environment correction coefficients to the charge bias.
2204 001
Environ. : HH: [K]
2204 002
Environ. : HH: [M]
2204 003
Environ. : HH: [C]
2204 004
Environ. : HH: [Y]
2204 006
Environ. : H: [K]
2204 007
Environ. : H: [M]
2204 008
Environ. : H: [C]
2204 009
Environ. : H: [Y]
2204 011
Environ. : MM: [K]
2204 012
Environ. : MM: [M]
2204 013
Environ. : MM: [C]
2204 014
Environ. : MM: [Y]
2204 016
Environ. : L: [K]
2204 017
Environ. : L: [M]
2204 018
Environ. : L: [C]
2204 019
Environ. : L: [Y]
*EGB
[0 to 1.5 / 0.30 / 0.01 mA/step]
*EGB
[0 to 1.5 / 0.30 / 0.01 mA/step]
*EGB
[0 to 1.5 / 0.30 / 0.01 mA/step]
*EGB
[0 to 1.5 / 0.30 / 0.01 mA/step]
*EGB
[0 to 255 / 204 / 1/step]
*EGB
[0 to 255 / 196 / 1/step]
*EGB
[0 to 255 / 197 / 1/step]
*EGB
[0 to 255 / 191 / 1/step]
*EGB
[0 to 255 / 197 / 1/step]
*EGB
[0 to 255 / 188/ 1/step]
*EGB
[0 to 255 / 190 / 1/step]
*EGB
[0 to 255 / 183 / 1/step]
*EGB
[0 to 255 / 187 / 1/step]
*EGB
[0 to 255 / 179 / 1/step]
*EGB
[0 to 255 / 179 / 1/step]
*EGB
[0 to 255 / 176 / 1/step]
*EGB
[0 to 255 / 195 / 1/step]
*EGB
[0 to 255 / 184 / 1/step]
*EGB
[0 to 255 / 184 / 1/step]
*EGB
[0 to 255 / 185 / 1/step]