5. Service Tables
2153 002
2153 003
5
2153 004
2153 005
2153 006
2153 008
178
Process Control
Initialization
Data In
Cut In
Job End
Trans. Belt Speed 2
Enables or disables the adjustment after
process control is done.
*EGB
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
Enables or disables the adjustment immediately
after the power is turned on or when recovering
from energy save mode.
*EGB
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
Enables or disables the adjustment immediately
after the machine starts to receive print job data.
The adjustment is done if one of the conditions
set with SP2153-012, -013 and –015 is
*EGB
satisfied.
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On
Enables or disables the adjustment during
printing. The adjustment is done if one of the
conditions set with SP2153-012, -013 and –
*EGB
015 is satisfied.
[0 or 1 / 1 / -] Alphanumeric
0: No, 1: Yes
Enables or disables the adjustment after
printing.
*EGB
[0 or 1 / 0 / -] Alphanumeric
0: Off, 1: On
Enables or disables the transfer belt speed
correction during the adjustment. The transfer
belt speed is affected by changes in
temperature. A change of the transfer belt
speed during the adjustment causes color
*EGB
registration errors. This SP keeps the transfer
belt at a constant speed.
[0 or 1 / 1 / -] Alphanumeric
0: Off, 1: On