When the "ON" is set, pre-rotation speed is the one-third of normal speed.
MM/HH: RotSpd. Sel
1912 017
Turns on or off the rotation speed switching of the pre-rotation in MM/HH condition.
When the "ON" is set, pre-rotation speed is the one-third of normal speed.
1913
[Heating Roller] Heating Roller Control
Stand-by Temp.
1913 002
Adjusts the heating roller temperature when the machine is in the ready condition.
1916
[Nip Measure] Fusing Nip Width Measurement DFU
Nip Measure Exe.
1916 001
Performs the nip width measurement.
Prerotation Time
1916 002
Adjusts the rotation time of the fusing unit rollers before the nip measurement.
[Environ. Adapt.] Fusing Idling: Environment Correction
The machine automatically adjusts the duration of fusing idling, depending on room
temperature measured by the temperature/humidity sensor
(Paper Type, Temperature Environment, Value of Temperature/ Rotation Time)
1917
Paper Type
2, SP: Special (see the Specifications table for details on these paper weights)
Temperature Environment -> H: High temperature, L: Low temperature
Value of Temperature/ Time: Dec.: Decrease, Inc.: Increase
1917 001
LL/MM Border
1917 002
LM Temp Adj.
[0 or 1 / 1 / 1]
*EGB
0: OFF, 1: ON
*EGB
[0 to 200 / 150 / 1deg /step]
[0 or 1 / 0 /-]
0: Not execute, 1: Execute
*EGB
[0 to 60 / 10 / 1 sec/step]
N1: Plain paper 1, N2: Plain paper 2, T1: Thick paper 1, T2: Thick paper
Adjusts the threshold degree between LL (Low
temperature and Low humidity) and MM (Middle
*EGB
temperature and middle humidity).
[0 to 35 / 23 / 1deg /step]
Adjusts the additional temperature for LM
*EGB
condition. This temperature is added to the fusing
temperature of MM condition.
Service Mode Table