Ricoh G-P3 Service Manual page 339

Table of Contents

Advertisement

5. Service Tables
2
3
4
• More than one event can be selected.
• Example 1: To Select Items 1, 2, 4
• Push the  or  key to select the appropriate items(s). Press the "OK" key for each selection.
This example shows "Engine SC Error" selected.
• Example 2: To Specify an SC Code
5
• Push the  or  key to select "3 Any SC Error", enter the 3-digit SC code number with the
 or  key. Then press"OK" key. This example shows an entry for SC670.
• For details about SC code numbers, please refer to the SC tables in Chpater 4.
"Troubleshooting".
5. Select one or more memory modules for reading and recording debug information. Select "SP5859".
Under "5859" press the necessary key item for the module that you want to record.
Enter the appropriate 4-digit number with the  or  key. Then press"OK".
• Refer to the two tables below for the 4-digit numbers to enter for each key.
The following keys can be set with the corresponding numbers. (The initials in parentheses indicate the
names of the modules.)
4-Digit Entries for Keys 1 to 10
Key No.
1
2
3
4
5
338
Controller SC Error
Any SC Error
Jam
Printer
2222 (SCS)
14000 (SRM)
256 (IMH)
1000 (ECS)
1025 (MCS)
Saves debug data when a controller-related SC
Code is generated.
Saves data only for the SC code that you specify by
entering code number.
Saves data for jams.