Ricoh G-P3 Service Manual page 113

Table of Contents

Advertisement

4. Troubleshooting
SC
[Level]
[00FF]: Detailed error code
[B]
Cache access error in the CPU
4
[0601, 0602, 0605, 0606, 0607, 0609]: Detailed error code
Exceptional command does
[B]
not operate even though it is
executed on purpose.
[B]
[060A-060E]: Detailed error code
Cut-in command does not
operate when it is executed.
[0610]: Detailed error code
[B]
Timer cut-in does not operate
even though it is set.
[0612]: Detailed error code
[B]
Cut-in in ASIC occurs.
[06FF]: Detailed error code
The pipeline clock frequency
[B]
rate is different from the
prescribed value.
[0702]: Detailed error code
[B]
112
Symptom
• Defective CPU
• Defective local bus
1. Turn the main power switch off and on.
2. Reinstall the system program.
3. Replace the controller board.
• Defective CPU devices
1. Replace the controller board.
• Defective CPU devices
• Defective ASIC devices
1. Replace the controller board.
• Defective CPU devices
1. Replace the controller board.
• Defective ASIC
• Defective devices in which ASIC detects cut-in.
1. Replace the controller board.
• Defective CPU devices
• Mode bit data error, which is used for initializing
1. Replace the controller board.
Possible Cause/Required Action
CPU.

Advertisement