5. Service Tables
2201 003
RS: [C]
2201 004
RS: [Y]
2201 006
LS: [K]
2201 007
LS: [M]
2201 008
LS: [C]
2201 009
LS: [Y]
[Charge Bias: AC] Charge Roller Voltage: AC
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular speed
2202
These SPs adjust the AC voltage of the drum charge roller. These are used only when
5
SP2-202-011 is set to "1".
2202 001
RS: [K]
2202 002
RS: [M]
2202 003
RS: [C]
2202 004
RS: [Y]
2202 006
LS: [K]
2202 007
LS: [M]
2202 008
LS: [C]
2202 009
LS: [Y]
2202 011
Output Control
2202 012
Interval
[Charge Bias: AC] Charge Roller Voltage: AC/I
2203
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular speed
182
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
[0 to 3000 / 2000 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
Selects the method for the charge roller AC bias
adjustment.
*EGB
[0 or 1 / 0 / -]
0: Process Control, 1: Setting
Adjusts the interval for charge roller AC bias
adjustment.
*EGB
[0 to 2000 / 210 / 1 sheet/step]