5. Service Tables
1917 003
H: Rotat. Time Dec.
1917 004
N1: H: Temp. Dec.
1917 005
N1: L: Temp. Inc.
5
1917 006
L: Rotat. Time Inc.
1917 007
H: Standard Temp.
1917 008
L: Standard Temp.
1917 009
L: Rotation Dec.
1917 010
N2: H: Temp. Dec.
1917 011
N2: L: Temp. Inc.
1917 012
TN: H: Temp. Dec.
1917 013
TN: L: Temp. Inc.
166
[0 to 30 / 4 / 1deg /step]
Adjusts the rotation time decrease at high
temperature.
*EGB
[-120 to 0 / 0 / 1 sec/step]
Adjusts the temperature decrease for plain paper
1 at high temperature.
*EGB
[-50 to 0 / 0 / 1deg /step]
Adjusts the temperature increase for plain paper
1 at low temperature.
*EGB
[0 to 30 / 10 / 1deg /step]
Adjusts the rotation time increase at low
temperature.
*EGB
[0 to 120 / 0 / 1 sec/step]
Sets the threshold temperature detected as high
temperature.
*EGB
[25 to 40 / 30 / 1deg /step]
Sets the threshold temperature detected as low
temperature.
*EGB
[-15 to 30 / 18 / 1deg /step]
Adjusts the rotation time decrease at low
temperature.
*EGB
[0 to 100 / 20 / 1 sec/step]
Adjusts the temperature decrease for plain paper
2 at high temperature.
*EGB
[-50 to 0 / 0 / 1 sec/step]
Adjusts the temperature increase for plain paper
2 at low temperature.
*EGB
[0 to 30 / 13 / 1deg /step]
Adjusts the temperature decrease for thin paper at
high temperature.
*EGB
[-50 to 0 / 0 / 1 sec/step]
Adjusts the temperature increase for thin paper at
*EGB
low temperature.