Ricoh G-P3 Service Manual page 194

Table of Contents

Advertisement

2456 007
T. Roll 2: 1st
2456 012
T. Roll 2: 2nd
[Normal2:[FC]:TE] Transfer roller current and discharge plate voltage for the trailing edge
area of plain paper 2 in color mode
2458
Paper Side: 1st or 2nd
2458 003
Separation
2458 007
T. Roll 2: 1st
2458 012
T. Roll 2: 2nd
[Spec1:[K]] Transfer roller current and discharge plate voltage for the leading edge area
of special paper 1 in B/W mode
2462
Paper Side: 1st or 2nd
2462 007
RS: 1st: T.Roll2
2462 008
RS: 1st:Separa.
2462 012
RS: 2nd: T.Roll2
2462 013
RS: 2nd: Separa.
[Spec1:[K]] Transfer roller current and discharge plate voltage for the trailing edge area
of special paper 1 in B/W mode
2463
Paper Side: 1st or 2nd
2463 007
LS: 1st: T.Roll2
2463 008
LS: 1st:Separa.
2463 012
LS: 2nd: T.Roll2
2463 013
LS: 2nd: Separa.
[Spec1:[FC]] Transfer roller current and discharge plate voltage for the leading edge
area of special paper 1 in color mode
2467
Paper Side: 1st or 2nd
2467 013
RS: 1st: T.Roll2
The value displayed on the LCD is different from
*EGB
these SP's values. For example, "20%" on the LCD
*EGB
actually means 100%.
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different from
*EGB
these SP's values. For example, "20%" on the LCD
*EGB
actually means 100%.
*EGB
[0 to 100 / 15.5 / 0.1 – A /step]
*EGB
[0 to 4 / 2 / 0.1 -kV/step]
*EGB
[0 to 100 / 25.0 / 0.1 -µA /step]
*EGB
[0 to 4 / 2 / 0.1 -kV/step]
*EGB
[0 to 100 / 12.5 / 0.1 -µA /step]
*EGB
[0 to 4 / 2 / 0.1 -kV/step]
*EGB
[0 to 100 / 20.0 / 0.1 -µA /step]
*EGB
[0 to 4 / 2 / 0.1 -kV/step]
*EGB
[0 to 100 / 18.5 / 0.1 -µA /step]
Service Mode Table
5
193

Advertisement

Table of Contents
loading

This manual is also suitable for:

G190

Table of Contents