SC
Symptom
[Level]
The result when the program is
executed in the command
cache is different from
desirable value.
[0709, 070A]: Detailed error code
Even you write the data in the
only cache of memory, the
[B]
data is actually written in
another area (not cache) of
memory.
[0801, 0804, 0807, 0808, 0809, 80A]: Detailed error code
[B]
An error occurs when
checking the TLB.
[4002-4005]: Detailed error code
[B]
The calculation error in the
CPU occurs.
821
Self-Diagnostic Error: ASIC
ASIC error
[0B00]
The write-&-verify check error
[B]
has occurred in the ASIC.
ASIC not detected
[0B06]
The ASIC of the I/O is not
[B]
detected.
[0B10]
SHM register check error
[B]
Possible Cause/Required Action
• Insufficient CPU cache
• Insufficient memory process speed
1. Replace the controller board.
2. Replace the RAM DIMM.
• Defective CPU devices
• Incorrect SPD
• Boot mode setting error
1. Replace the controller board.
2. Replace the RAM DIMM.
• Defective CPU devices
1. Replace the controller board.
• Defective CPU
1. Replace the CPU.
• Defective controller board
1. Replace the controller.
• ASIC (controller board defective)
• Poor connection between North Bridge and PCI I/
F.
1. Replace controller board.
Service Call Conditions