1917 014
TC1: H: Temp. Dec.
1917 015
TC1: L: Temp. Inc.
1917 016
TC2: H: Temp. Dec.
1917 017
TC2: L: Temp. Inc.
1917 018
OHP: H: Temp. Dec.
1917 019
OHP: L: Temp. Inc.
1917 020
SP: H: Temp. Dec.
1917 021
SP: L: Temp. Inc.
1917 022
ENV:H:Temp. Inc.
1917 023
ENV:L:Temp. Inc.
1917 024
GL:H:Temp. Inc.
[0 to 30 / 10 / 1deg /step]
Adjusts the temperature decrease for thick paper
1 at high temperature.
*EGB
[-50 to 0 / 0 / 1 sec/step]
Adjusts the temperature increase for thick paper 1
at low temperature.
*EGB
[0 to 30 / 10 / 1deg /step]
Adjusts the temperature decrease for thick paper
2 at high temperature.
*EGB
[-50 to 0 / 0 / 1 sec/step]
Adjusts the temperature increase for thick paper 2
at low temperature.
*EGB
[0 to 30 / 10 / 1deg /step]
Adjusts the temperature decrease for OHP at high
temperature.
*EGB
[-50 to 0 / 0 / 1 sec/step]
Adjusts the temperature increase for OHP at low
temperature.
*EGB
[0 to 30 / 10 / 1deg /step]
Adjusts the temperature decrease for special
paper at high temperature.
*EGB
[-50 to 0 / 0 / 1 sec/step]
Adjusts the temperature increase for special paper
at low temperature.
*EGB
[0 to 30 / 10 / 1deg /step]
Adjusts the temperature increase for envelop at
high temperature.
*EGB
[-50 to 0 / 0 / 1deg /step]
Adjusts the temperature increase for envelop at
low temperature.
*EGB
[0 to 30 / 7 / 1deg /step]
Adjusts the temperature increase for glossary
*EGB
paper at high temperature.