Adjusts the threshold temperature for the added idling rotation.
1st Pot Add Time
1104 031
Adjusts the added idling rotation time. This SP is activated when the fusing temperature
does not reach the specified temperature with SP1104-30.
[Fusing Temp.] Fusing Temperature
(Paper Type, Mode, Color, Process Speed)
Paper Type -> N: Plain paper 1, N2: Plain paper 2, TC: Thick, TN: Thin, SP: Special,
OHP, ENV: Envelope, GL: Glossy paper, TK2: Thick paper 2
Mode -> Simple [one-sided] or Duplex
1105
Color -> K: Black only, FC: Full color
Process Speed -> LS: Low speed, RS: Regular speed
Reload: Print ready, between jobs
Adjusts the fusing unit temperature for each mode.
1105 022
Reload Temp.
1105 025
TC1: Simple: [K]
1105 026
TC1: Duplex: [K]
1105 027
TC1: Simple: [FC]
1105 028
TC1: Duplex: [FC]
1105 029
TC2: Simple: [K]
1105 031
TC2: Simple: [FC]
1105 033
N: Simple: [K]: LS
1105 034
N: Simple: [K]: RS
1105 035
N: Duplex: [K]: LS
1105 036
N: Duplex: [K]: RS
1105 037
N: Simple: [FC]: LS
1105 039
N: Simple: [FC]: RS
1105 040
N: Duplex: [FC]: LS
*EGB
[0 to 10 / 2 / 0.1 sec/step]
*EGB
[100 to 180 / 160 / 1deg /step]
*EGB
*EGB
*EGB
[120 to 180 / 160 / 1deg /step]
*EGB
*EGB
*EGB
*EGB
[120 to 180 / 145 / 1deg /step]
*EGB
[120 to 180 / 160 / 1deg /step]
*EGB
[120 to 180 / 145 / 1deg /step]
*EGB
[120 to 180 / 160 / 1 deg /step]
*EGB
[120 to 180 / 145 / 1deg /step]
*EGB
[120 to 180 / 160 / 1deg /step]
*EGB
[120 to 180 / 145 / 1deg /step]
Service Mode Table