5. Service Tables
SP9-XXX
9001
[Shutter Motor]
9001 064
Open Time
9001 065
Close Time
[Filming Remov.] Filming Removal
9001 074
Interval: [k]
5
[Vb: LS] Vb at Low Process Speed
9001 083
Vb Shift
[Vc: LS] Vc at Low Process Speed
9001 084
Vc Shift
[Filming Remov.] Filming Removal: Job end
9001 099
Interval (E): [K]
9001 100
Interval (E): [FC]
9001 101
Interval: [end]
9001 102
Vk Coef.
9001 103
314
Adjusts the open shutter time.
*EGB
[0 to 990 / 210 / 10 ms/step]
Adjusts the closed shutter time.
*EGB
[0 to 990 / 100 / 10 ms/step]
Adjusts the threshold for filming removal. This SP is
executed even the print job is proceeding.
*EGB
[0 to 65535 / 150 / 1/step]
*EGB
[0 to 65535 / 10 / 1/step]
*EGB
[0 to 65535 / 0 / 1/step]
Displays the counter that counts the number of
sheets in black and white printing mode from
*EGB
previous filming removal.
[0 to 65535 / 0 / 1/step]
Displays the counter that counts the number of
sheets in full color printing mode from previous
*EGB
filming removal.
[0 to 65535 / 0 / 1/step]
Adjusts the threshold for job end filming removal.
This SP is not executed until the print job has ended.
*EGB
[0 to 65535 / 75 / 1/step]
[0.00 to 1.00 / 0.00 / 0.01 /step]
[0 to 100 / 100 / 1%/step]

Advertisement