5. Service Tables
1911 003
PPM Down Inter.
1911 004
S-size Temp. 1
1911 006
S-size Temp. 2
1911 008
S-size Temp. 3
1911 014
S-size Temp.: S1
5
1911 016
S-size Temp.: S2
1911 018
S-size Temp.: S3
1911 020
Simple Temp. 3
1911 021
Simple Temp. 1
1911 022
Simple Temp. 2
1911 023
Simple Temp.:S1
1911 024
Simple Temp.:S2
1911 025
Duplex Temp. 1
162
The print speed goes back to the normal speed
after this interval.
*EGB
[0 to 255 / 30 / 1 sec/step]
The temperature is decreased by this amount to
prevent overheating the fusing unit for small size
*EGB
paper.
[0 to 200 / 2 / 1deg /step]
*EGB
[0 to 200 / 5 / 1deg /step]]
*EGB
These SPs control when the above temperature
reductions are done.
*EGB
[0 to 255 / 25 / 1 sheet/step]
*EGB
[0 to 255 / 10 / 1 sheet/step]
*EGB
[0 to 255 / 15 / 1 sheet/step]
This SP controls when the temperature reduction of
SP1911-022 is done.
*EGB
[0 to 500 / 15 / 1 sheet/step]
Adjusts the temperature reduction for one-sided
printing.
*EGB
[0 to 200 / 2 / 1deg /step]]
Adjusts the temperature reduction 2 for one-sided
printing.
*EGB
[0 to 200 / 5 / 1deg /step]]
This SP keeps the target print temperature for
specified printouts with this SP.
*EGB
[0 to 500 / 100 / 1 sheet/step]
This SP controls when the temperature reduction of
SP1911-021 is done.
*EGB
[0 to 500 / 10 / 1 sheet/step]
Adjusts the temperature reduction for duplex
printing.
*EGB
[0 to 200 / 2 / 1deg /step]]