[Coverage Range]
Sets the color coverage threshold.
Coverage rate = Coverage per page / A4 full coverage (dots) x 100
There are three coverage counters: Color 1, Color 2, and Color 3
• [A] 5 % (default) is adjustable with SP7855-001.
• [B] 20 % (default) is adjustable with SP7855-002.
7855
• The setting value [B] must be set larger than [A].
The total numbers of printouts (BW printing plus color printing) for each coverage range
are displayed with the following SPs.
• Color1 counter: SP8601-021
• Color2 counter: SP8601-022
• Color3 counter: SP8601-023
7855 001
Coverage Range 1
7805 002
Coverage Range 2
7901
[Assert Info]
7901 001
File Name
7901 002
Number of Lines
7901 003
Location
[PM Counter-PREV] Previous Preventive Maintenance Counter Display
7906
(Sheets or Rotation (%),Unit, [Color]) Trans Belt Unit: Transfer Belt Unit, T. Roll 2: Transfer
Roller 2, Waste Toner: Waste Toner Bottle, Toner: Toner Bottles
7906 001
S: PCU: [K]
7906 002
S: PCU: [M]
7906 003
S: PCU: [C]
*CTL
[1 to 200 / 5 /1]
*CTL
[1 to 200 / 20 /1]
*CTL
Records the location where a problem is detected
*CTL
in the program. The data stored in this SP is used
for problem analysis.
*CTL
*EGB
Displays the number of sheets printed with the
*EGB
previous maintenance units.
[0 to 9999999 / 0 / 1/step]
*EGB