5. Service Tables
1104
[Fusing Cont.] Fusing Control
Control Method
1104 001
Selects the fusing control method.
0: ON/OFF Control, 1: PID Control (Phase control)
Max. Wait Time
1104 022
Adjusts the maximum waiting time for the target printing temperature of fusing unit. After
this interval, printing will start if the temperature did not get to the target.
Paper Feed. Temp.
1104 023
Adjusts the increase in the temperature of the fusing unit between the ready condition and
the start of paper feed at the start of a new job.
5
1st Add Time: LS
1104 024
For print jobs at low speed. If the interval between jobs is less than this setting, then the
temperature change (1104 025) for the first page of a new job is not applied.
1st Add Temp.
Adds this value to the basic fusing temperature, for the first page of a new job. This extra
1104 025
temperature is necessary because when the printer starts the first page, the fusing unit is
not warm enough.
1st Temp. Maint.
1104 026
Adjusts the time for maintaining the temperature change that is set with 1104 025.
1st Print Inter.
1104 027
For print jobs at regular speed. If the interval between jobs is less than this setting, then
the temperature change (1104 025) for the first page of a new job is not applied.
Paper Feed. Temp.
1104 028
Adjusts the increase in the temperature of the fusing unit between the ready condition and
the start of paper feed at the start of a new job (B/W mode).
1st PrtDecTmpTime
1104 029
Adjusts the time for decreasing 1°C when the temperature decline to the target printing
temperature.
PreRot.Thre.Temp.
1104 030
158
*EGB
[0 or 1 / 1 / -]
*EGB
[0 to 255 / 30 / 1 sec/step]
*EGB
[0 to 30 / 10 / 1deg /step]
[0 to 50 / 0 / 0.1 sec/step]
*EGB
[0 to 20 / 8 / 1deg /step]
*EGB
[0 to 50 / 8 / 1 sec/step]
*EGB
[0 to 100 / 0 / 0.1 sec/step]
*EGB
[0 to 30 / 5 / 0.1 deg/step]
*EGB
[0 to 255 / 3 / 1 sec/step]
*EGB
[0 to 255 / 20 / 1 deg/step]