2111
[Manual Execut.] Manual Line Position Adjustment Execution
2111 001
Position Adjust.
2111 002
Pro. Position Adj.
2111 003
Skew Adjust.
2111 004
ID S. Adjust.
2111 005
Area.Magni.Clr.
2120
[LD Off Check]
[ID S. Display] ID Sensor Display
2143
The ID sensor assembly has three sensors: Left, Center, Right
2143 001
PWM: Left
2143 002
PWM: Center
2143 003
PWM: Right
2143 004
Avg: Left
2143 005
Avg: Center
2143 006
Avg: Right
2143 007
Max: Left
2143 008
Max: Center
2143 009
Max: Right
2143 010
Min: Left
2143 011
Min: Center
2143 012
Min: Right
2143 013
Max2: Left
2143 014
Max2: Center
2143 015
Max2: Right
2143 016
Min2: Left
Performs the line position adjustment.
Performs an approximate line position adjustment.
Performs the skew adjustment.
Tests the ID sensor.
Clears the area magnification setting.
Displays the LD off check state.
*EGB
Displays the PWM value for each sensor.
*EGB
[0 to 512 / 0 / 1/step]
*EGB
*EGB
Displays the average output from each sensor.
*EGB
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
*EGB
*EGB
Displays the maximum output from each sensor.
*EGB
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
*EGB
*EGB
Displays the minimum output from each sensor.
*EGB
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
*EGB
*EGB
Displays the maximum 2 output from each sensor.
*EGB
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
*EGB
*EGB
Displays the maximum 2 output from each sensor.
Service Mode Table