Ricoh G-P3 Service Manual page 251

Table of Contents

Advertisement

5. Service Tables
5th and 6th digits: The hour. [00 to 23]
7th digit: The length of the advanced time. [0 to 9 / 1 hour /step]
8th digit: The length of the advanced time. [0 to 5 / 10 minutes /step]
For example: 3500010 (EU default)
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
5307 004
Rule Set(End)
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
5
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
5401
[Access Control]
5401 200 SDK1 Unique ID
5401 201 SDK1 Certification
Method
5401 210 SDK2 Unique ID
5401 211 SDK2 Certification
Method
5401 220 SDK3 Unique ID
5401 221 SDK3 Certification
Method
5404
[User Code Clear] User Code Counter Clear
250
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
-
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
NA: 105(4)60000, EU: 105(4)00000,
ASIA: 03100000
*CTL
"SDK" is the "Software Development Kit". These
data can be converted from SAS (VAS) when
installed or uninstalled. DFU
*CTL
*CTL
*CTL
*CTL
*CTL