Ricoh G-P3 Service Manual page 102

Table of Contents

Advertisement

SC
Symptom
[Level]
The charge current less than
200 µA is detected.
Charge AC bias error [M]
305
The charge current less than
[D]
200 µA is detected.
Charge AC bias error [C]
306
The charge current less than
[D]
200 µA is detected.
Charge AC bias error [Y]
307
The charge current less than
[D]
200 µA is detected.
Possible Cause/Required Action
• Defective charge roller
• Defective connectors
• Disconnected harness
• Defective high voltage power 1
1. Check the connectors.
2. Replace the PCU for black.
3. Replace the drum positioning plate.
4. Replace the high voltage power 1.
• Defective charge roller
• Defective connectors
• Disconnected harness
• Defective high voltage power 1
1. Check the connectors.
2. Replace the PCU for magenta.
3. Replace the drum positioning plate.
4. Replace the high voltage power 1.
• Defective charge roller
• Defective connectors
• Disconnected harness
• Defective high voltage power 1
1. Check the connectors.
2. Replace the PCU for cyan.
3. Replace the drum positioning plate.
4. Replace the high voltage power 1.
• Defective charge roller
• Defective connectors
Service Call Conditions
4
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

G190

Table of Contents