Ricoh G-P3 Service Manual page 187

Table of Contents

Advertisement

5. Service Tables
2306 002
Correction Coef.
2314
[Trans.Belt Bias] Transfer Belt Current at Process Control
2314 011
Process Cont. [K]
2314 012
Process Cont. [M]
2314 013
Process Cont. [C]
5
2314 014
Process Cont. [Y]
[T.Roll2 Clean.] Transfer Roller Cleaning
2326
(Positive or Negative Bias, Process Speed) Process Speed -> RS: Regular speed, LS: Low
speed
2326 002
Posi. Bias: RS
2326 003
Posi. Bias: LS
2326 005
Nega. Bias: RS
2326 006
Nega. Bias: LS
[Trans.Belt Bias] Transfer Belt Current
2352
([Color], Process Speed) Process Speed -> RS: Regular speed
2352 001
[K]: RS
[Trans.Belt Bias] Transfer Belt Current
2353
([Color], Process Speed) Process Speed -> LS: Low speed
2353 001
[K]: LS
186
Adjusts the Vd link correction coefficient.
*EGB
[1.00 to 2.50 / 1.00 / 0.01/step]
Adjusts the transfer belt current at process control
for [K].
*EGB
[0 to 60 / 13.0 / 0.1 µA /step]
*EGB
Adjusts the transfer belt current at process control
for [M, C].
*EGB
[0 to 60 / 10.0 / 0.1 µA /step]
Adjusts the transfer belt current at process control
for [Y].
*EGB
[0 to 60 / 13.0 / 0.1 µA /step]
*EGB
Adjusts the positive voltage for transfer roller
cleaning.
*EGB
[0 to 2 / 2.0 / 0.1 KV/step]
*EGB
Adjusts the negative voltage for transfer roller
cleaning.
*EGB
[0 to 60 / 60.0 / 0.1V/step]
Adjusts the current that is applied to the transfer belt.
[0 to 60 / 17.0 / 0.1 µA /step]
*EGB
Adjusts the current that is applied to the transfer belt.

Advertisement

Table of Contents
loading

This manual is also suitable for:

G190

Table of Contents