Ricoh G-P3 Service Manual page 182

Table of Contents

Advertisement

2181 038
[Y]: S Cor.: 1200
[MUSIC Record] Automatic Line Position Adjustment Record
2186
The following SPs display the MUSIC record.
2186 001
Year
2186 002
Month
2186 003
Date
2186 004
Time
2186 005
Minute
2186 006
Temperature
2186 007
Result
2186 008
Execution
2186 009
Failure
[MUSIC Result] Automatic Line Position Adjustment Result
2187
The following SPs display the skew adjustment values after the line position adjustment
have been done.
2187 001
[K]:Skew Adj.
2187 002
[M]:Skew Adj.
2187 003
[C]:Skew Adj.
2187 004
[Y]:Skew Adj.
[Charge Bias: DC] Charge Roller Voltage: DC
(Process Speed, [Color]) Process Speed LS: Low speed, RS: Regular speed
2201
These SPs adjust the DC voltage of the drum charge roller. These are used only when
SP3-501-001 is set to "1".
2201 001
RS: [K]
2201 002
RS: [M]
*EGB
[-256 to 256 / 0 / 1 line/step]
*EGB
[0 to 99 / 0 / 1 y/step]
*EGB
[1 to 12 / 1 / 1 m/step]
*EGB
[1 to 31 / 1 / 1 d/step]
*EGB
[0 to 23 / 0 / 1 h/step]
*EGB
[0 to 59 / 0 / 1 m/step]
*EGB
[0 to 100 / 0 / 1deg/step]
*EGB
[0 to 999999 / 0 / 1 /step]
*EGB
[0 to 9999 / 0 / 1 /step]
*EGB
[0 to 9999 / 0 / 1 /step]
*EGB
*EGB
[-99 to 99 / 0 / 1 click/step]
*EGB
*EGB
*EGB
[200 to 999 / 585 / 1 V/step]
*EGB
Service Mode Table