Ricoh G-P3 Service Manual page 171

Table of Contents

Advertisement

5. Service Tables
2104 002
[M]: M Magnifi.
2104 003
[C]: M Magnifi.
2104 004
[Y]: M Magnifi.
[LD Power Cont.] LD Power Control
2105
([Color], Process Speed) Process Speed -> LS: Low speed, RS: Regular speed
2105 001
[K] 0
2105 002
[M] 0
2105 003
[C] 0
2105 004
[Y] 0
5
2105 009
[K] 0: LS
2105 010
[M] 0: LS
2105 011
[C] 0: LS
2105 012
[Y] 0: LS
2106
Polygon Motor Stop Time
2106 001
2109
[LD BeamPattern] LD Beam Pattern
2109 001
Picture Addition
2109 002
Pattern Select
2109 004
Color Select
170
*EGB
[-1.00 to 1.00 / 0.00 / 0.01%/step]
*EGB
*EGB
*EGB
*EGB
Adjusts the LD power.
[10 to 200 / 100 / 1%/step] DFU
*EGB
*EGB
*EGB
*EGB
Adjusts the LD power at low speed.
[10 to 200 / 100 / 1%/step] DFU
*EGB
*EGB
Adjusts the time to stop the polygon motor after
job end.
*EGB
[0 to 180 / 10 / 1 sec/step]
Adds the picture to the LD test pattern.
[0 or 1 / 0 /-]
0: Not execute, 1: Execute
Selects the LD test pattern.
[0 to 24 / 0 / 1/step]
Selects the color for the LD test pattern.
[0 to 4 / 0 / 1/step]