cylinders and check again CO level once idling rpm is correct.
If adjustment results were negative, repeat the procedure, starting from throttle position sensor (TPS) reset.
Note
The vacuum gauge is not used since "cylinder synchronisation procedure" is not necessary.
Adjusting the choke
Work the choke control adjuster (22) to adjust choke lever (23) so that the lever (24) can travel smoothly all its
stroke.
Checking engine oil pressure
Note
A table at the end of this section explains the icons used in this procedure.
Take oil circuit pressure through engine oil pressure sensor outlet (21) as follows:
Remove the pressure switch (21) connector (A). Be sure to collect the seal.