Head unit: checks and adjustments
Turn degree wheel (G) counter clockwise until dial gauge (C) placed at the exhaust end reads 1 mm lift. Check that
angle reading in degrees on the degree wheel (G) is as specified (Sect. C 1.1, Timing/valves).
Rotate in the same direction until obtaining 1 mm lift on the intake end. Check degrees on degree wheel.
Rotate again until valve is fully closed during the combustion stroke.
Reverse rotation (i.e., turn clockwise) of degree wheel (G) until gauge (C) points 1 mm lift of intake valve. Check
degrees again.
Rotate clockwise again until obtaining 1 mm lift of the exhaust valve.
Check degrees again.
Repeat procedure for vertical cylinder.
Allowed tolerance for measured values is ±3° with respect to specified values.
Remove the tools used to check engine timing.
Operations
Refit the valve covers
Refit side timing covers
file:///C|/Documents%20and%20Settings/F4i/My%...manual/wsm/usa/Mon695_MY07_N_4A9_00.62.1.html (8 of 8) [10/7/2008 8:45:21 PM]
Reference See Section
N 4.3,
Refitting the valve covers
N 4.2,
Refitting the timing side covers