Maintenance operations
If you do not have a brake bleeder available, connect a length of transparent plastic tubing to the bleed valve as
outlined in the draining procedure.
Open the bleed valve by one fourth of a turn and operate the brake lever (or pedal) several times until the fluid
starts coming out of the bleed valve.
Pull the lever or pedal fully in and slacken the bleed valve by at least one fourth one fourth of a turn.
Allow several seconds and then release the lever (or pedal) gradually and close the bleed valve (2) or (4).
Caution
Do not release the brake lever (or pedal) until the bleed valve has been fully tightened.
Repeat the bleeding operation until air bubbles no longer come out of the plastic tube.
Bleed all bleed valves on the calipers one at a time.
Tighten the bleed valve (2) or (4) to the specified torque (Sect. C 3,
file:///C|/Documents%20and%20Settings/F4i/My...anual/wsm/usa/Mon695_MY07_D_4_5_00.18.1.html (12 of 29) [10/7/2008 8:42:49 PM]
Frame torque
settings). Fit the protection cap.