Chapter 16: SNTP Client Commands

CLOCK SUMMER-TIME

340
Syntax
clock summer-time
Parameters
None
Mode
Global Configuration mode
Description
Use this command to enable Daylight Savings Time (DST) on the SNTP
client.
Note
The switch does not set the DST automatically. If the switch is in a
locale that uses DST, you must remember to enable this when DST
begins and disable when DST ends. If the switch is in a locale that
does not use DST, set this option to disabled all the time. To disable
DST on the client, refer to "NO CLOCK SUMMER-TIME" on
page 342.
Confirmation Command
"SHOW NTP ASSOCIATIONS" on page 347
Example
The following example enables DST on the SNTP client:
awplus> enable
awplus# configure terminal
awplus(config)# clock summer-time