Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules.
Translated Safety Statements Important: Appendix B contains translated safety statements for installing this equipment. When you see the , go to Appendix B for the translated safety statement in your language. Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn sehen, schlagen Sie in Anhang B den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Contents Figures....................................5 Tables ....................................6 Preface ....................................7 Safety Symbols Used in this Document..........................8 Where to Find Web-based Guides ............................9 Contacting Allied Telesyn ..............................10 Online Support ................................10 Email and Telephone Support ............................10 Returning Products................................10 Sales or Corporate Information .............................10 Management Software Updates ............................10 Chapter 1: Overview ................................11 Features ....................................12 Front and Back Panels .................................13...
Page 6
Contents Appendix A: Technical Specifications ..........................42 Physical Specifications .................................42 Environmental Specifications..............................42 Power Specifications................................42 Safety and Electromagnetic Emissions Certifications......................43 Connectors and Port Pinouts ..............................43 Appendix B: Translated Safety Statements ........................45...
Figure 1. AT-FS750/16 and AT-FS750/24 Front Panels ....................13 Figure 2. AT-FS750/16 and AT-FS750/24 Back Panels..................... 13 Figure 3. AT-FS750/16 and FS750/24 System and Port LEDs ..................16 Figure 4. Power Workgroup Topology ..........................22 Figure 5. Collapsed Backbone - Hub Topology ........................23 Figure 6.
Preface This guide contains instructions on how to install the AT-FS750/16 and AT- FS750/24 Fast Ethernet Smart switches. This preface contains the following sections: “Safety Symbols Used in this Document” on page 8 “Where to Find Web-based Guides” on page 9...
Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesyn products are available in portable document format (PDF) on our web site at www.alliedtelesyn.com. You can view the documents online or download...
To obtain an RMA number, contact Allied Telesyn Technical Support through our web site: www.alliedtelesyn.com. Sales or You can contact Allied Telesyn for sales or corporate information through our web site: www.alliedtelesyn.com. To find the contact information for Corporate your country, select Contact Us -> Worldwide Contacts. Information...
Chapter 1 Overview The AT-FS750/16 and AT-FS750/24 are Layer 2 Fast Ethernet switches designed to simplify the task of creating or expanding an Ethernet or Fast Ethernet network. This chapter contains the follows sections: “Features” on page 12 “Front and Back Panels” on page 13 “Ports”...
Chapter 1: Overview Features The features of the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches include: LEDs for unit and port status 16 or 24 Auto-Negotiating 10/100Base-T twisted pair ports with RJ-45 connectors Two uplink combo ports (combination of one 10/100/1000Base-T...
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Front and Back Panels Figure 1 illustrates the front panels of the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches. AT-FS750/16 AT-FS750/16 16-Port 10/100Mbps + 2 SFP/1000T Combo WebSmart Switch SPEED LINK/ACT...
10 Mbps and 100 Mbps speeds, the uplink Ports combo ports are there to provide fiber optic connectivity for the 1000 Mbps speed. Each uplink combo port consists of one 10/100/1000Base-T twisted pair port and one SFP port (ports 17 and 18 on the AT-FS750/16,...
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide and ports 25 and 26 on the AT-FS750/24). If both uplink ports are connected, the SFP port takes precedent over the twisted pair port. RS-232 Console The RS-232 console port uses the management cable supplied with the switch.
LINK/ACT 1000M SPEED 100M LINK/ACT LINK/ACT POWER Figure 3. AT-FS750/16 and FS750/24 System and Port LEDs Table 2 describes the AT-FS750/16 and AT-FS750/24 system LEDs. Table 2. System LEDs State Description POWER The switch is not receiving power. The switch is receiving power.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Table 3. 10/100Base-T Port LEDs (Continued) State Description LINK/ACT Green A valid link has been established on the port. Blinking The port is transmitting or receiving data. Green No link is established on the port.
Chapter 1: Overview Power Supply The switches have an internal power supply with a single AC power supply socket on the back panel which features autoswitch AC inputs. To power the switch on or off, connect or disconnect the power cord provided with the switch.
NIC already has a MAC address assigned to it by its manufacturer. The MAC address table in the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches can store up to 8K MAC addresses. The switch...
The twisted pair ports on the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches can operate in either half-or full-duplex mode. They are IEEE 802.3u-compliant and use Auto-Negotiation to set the duplex mode setting for you automatically.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Back Pressure To maintain the orderly movement of data between the end nodes, an Ethernet switch may periodically need to signal an end node to stop and Flow Control sending data. This can occur under several circumstances. For example, if...
Chapter 1: Overview Network Topologies This section illustrates two network topologies that you can create with the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches: a power workgroup and collapsed backbone. Both types of topologies are described below. Power The topology shown in Figure 4 is commonly referred to as a power workgroup topology.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Collapsed In the topology illustrated in Figure 5, an AT-FS750/16 connects Fast Ethernet switches that have Fast Ethernet uplinks. This type of topology is Backbone often referred to as a collapsed backbone topology. The switch functions...
Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 25 “Selecting a Site for the Switch” on page 27 “Cabling” on page 28 “Unpacking the Switch” on page 29 “Installing the Switch on a Desktop” on page 30 “Installing a Switch in a Rack”...
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the chassis or any of its components. Note When you see the , go to Appendix B, “Translated Safety Statements”...
Page 28
Chapter 2: Installation Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over.
Chapter 2: Installation Cabling Table 5 contains the cabling specifications for the twisted pair ports. Table 5. Twisted Pair Cabling and Distances Maximum Speed Type of Cable Operating Distance 10 Mbps Category 3 or better 100-ohm 100 m (328 ft) shielded or unshielded twisted pair cable 100 Mbps...
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Unpacking the Switch To unpack the switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesyn.
Chapter 2: Installation Installing the Switch on a Desktop You can place the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches on a desktop or install them in a 19-inch rack. To install the switch in a rack, refer to “Installing a Switch in a Rack” on page 31.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Installing a Switch in a Rack To install the AT-FS750/16 or AT-FS750/24 switch in a rack, perform the following procedure: 1. If attached, remove the rubber feet using a flat-head screwdriver.
Chapter 2: Installation 4. Mount the switch on a 19-inch rack using the four large screws included. Figure 9 shows how to mount the AT-FS750/16 switch, and Figure 10 shows how to mount the AT-FS750/24 switch. Figure 9. Mounting the AT-FS750/16 Switch on the Rack Figure 10.
Page 35
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Warning: Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
Chapter 2: Installation Installing an Optional SFP Transceiver The AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches each have two SFP uplink ports. To install an SFP transceiver, perform the following procedure: Note The transceiver can be hot-swapped; you do not need to power off the switch to install a transceiver.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide 4. Slide the SFP transceiver into an SFP slot on the switch, as shown in Figure 12. Figure 12. Inserting the SFP 5. Repeat steps 2 through 4 if you are installing another SFP transceiver.
2. Connect the other end of the twisted pair cable to a port in the end node. Connecting the To connect a fiber optic cable to an SFP installed in the AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart switches, perform the following Fiber Optic...
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide 1. Remove the dust plug from the SFP, as shown in Figure 14. Figure 14. Removing the Dust Plug from the SFP 2. Connect the fiber optic cable to the SFP port, as shown in Figure 15.
Chapter 2: Installation Figure 16. Plugging in the AC Power Cord 2. Plug the other end of the power cord into a wall outlet. Warning: Power cord is used as a disconnection device. To de- energize equipment, disconnect the power cord. Pluggable Equipment.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Starting a Local Management Session Starting a Local To start a local management session on an AT-FS750/16 or AT-FS750/24 Smart switch, perform the following procedure: Management Session 1. Connect one end of the management cable to the console port on the switch, as shown in Figure 17.
Chapter 2: Installation The Login Menu is shown in Figure 18. ======================================================== AT-FS750/16 Local Management System Local - Console Allied Telesyn International Corp. Copyright, 2005 ======================================================== Login Menu Login: Password: Figure 18. Login Menu 4. Enter “manager” for the login name and press Return.
Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch in the event that a problem occurs. Note If you need further assistance, please contact Allied Telesyn Technical Support. Refer to “Contacting Allied Telesyn” on page 10. Check the POWER LED on the front of the switch.
-25° C to 70° C (-13° F to 158° F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Operating Altitude Range: Up to 3,000 m (9,843 ft) Power Specifications Input Supply Voltage: 100 - 240 VAC Power Consumption: AT-FS750/16 12.5 Watts AT-FS750/24 15 Watts...
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Safety and Electromagnetic Emissions Certifications EMI/RFI: FCC Class A, EN55022 Class A, CISPR Class A, C-TICK, CE Immunity: EN55024 Electrical Safety: EN60950 (TUV), UL60950 ( Connectors and Port Pinouts This section lists the connectors and connector pinouts for the AT-GS950/16 and AT-GS950/24 switches and their components.
Appendix A: Technical Specifications Table 7 lists the RJ-45 port pin signals when a twisted pair port is operating in the MDI-X configuration. Table 7. MDI-X Pin Signals (10Base-T or 100Base-TX) Signal Table 8 lists the RJ-45 connector pins and their signals when a 1000Base-T port is operating at 1000 Mbps.
Appendix B Translated Safety Statements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Appendix B: Translated Safety Statements Laser Safety Notices Warning: Class 1 Laser product. Warning: Do not stare into the laser beam. Electrical Safety Notices Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician.
Page 49
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Warning: Check to see if there are any exposed copper strands coming from the installed wire. When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block. Any exposed wiring can conduct harmful levels of electricity to persons touching the wires.
Page 50
Appendix B: Translated Safety Statements Warning: Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading. Warning: Remove all metal jewelry, such as rings and watches, before installing or removing a line card from a powered-on chassis.
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Telecommunications Compliance Notices Warning: When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electronic shock, and injury to persons, including the following: Do not use this product near water, for example, near a bathtub, washbowl, kitchen sink, or laundry tub in a wet basement or near a swimming pool.
Page 52
Appendix B: Translated Safety Statements Lasersicherheitshinweise Achtung: Laserprodukt der Klasse 1. Achtung: Blicken Sie nicht in den Laserstrahl. Elektrische Sicherheitshinweise Achtung: Um Stromschläge zu vermeiden, darf die Abdeckung nicht entfernt werden. Die Ausrüstung enthält keine benutzerwartbaren Teile. Diese Einheit führt gefährliche Spannungen und sollte nur durch einen ausgebildeten und qualifizierten Techniker geöffnet werden.
Page 53
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Achtung: Nicht mehr als die empfohlene Kabellänge abisolieren. Durch das Abisolieren von mehr als der empfohlenen Länge können gefährliche blanke Drähte aus dem Anschlussblock hervorragen. Achtung: Beim Installieren dieser Ausrüstung ist stets darauf zu achten, dass die Rahmenerdung zuerst angeschlossen und zuletzt abgetrennt wird.
Page 54
Appendix B: Translated Safety Statements Bei der Versorgung der Einheit durch zentralisierten Gleichstrom ist ein Tray-Kabel zum Anschluss der Stromquelle erforderlich. Das Tray-Kabel muss ein UL-gelistetes Typ-TC-Tray-Kabel mit einer Nennspannung von 600 V und einer Nenntemperatur von 90 Grad Celsius, mit drei Leitern und mindestens 14 AWG sein. Achtung: Bei der Rackmontage der Ausrüstung ist darauf zu achten, dass keine Gefahrenbedingung durch ungleichmäßige mechanische Belastung geschaffen wird.
Page 55
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Telekommunikationskonformitätshinweise Achtung: Bei der Verwendung Ihrer Telefonausrüstung sollten zur Reduzierung der Brand-, Stromschlag und Verletzungsgefahr stets grundsätzliche Sicherheitsrichtlinien, einschließlich der folgenden, befolgt werden: Verwenden Sie dieses Produkt nicht in der Nähe von Wasser, zum Beispiel in der Nähe einer Badewanne, einer Waschschüssel, eines Spülbeckens, eines...
Page 56
Appendix B: Translated Safety Statements Avisos de seguridad láser Atención: Producto láser de clase 1. Atención: No mire el rayo láser. Avisos de seguridad eléctricas Atención: Para evitar la electrocución, no quite la tapa. La unidad no contiene piezas que pueda reparar el usuario. Esta unidad contiene tensiones peligrosas y sólo la debe abrir un técnico convenientemente formado y cualificado.
Page 57
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Atención: Cuando instale el equipo, asegúrese de instalar primero la conexión a tierra del bastidor y de desconectarla en último lugar. Atención: Compruebe si hay algún hilo de cobre al descubierto que proceda del cable instalado.
Page 58
Appendix B: Translated Safety Statements Atención: Si el equipo se monta en un rack, se deberá evitar todo peligro de irregularidad en la carga mecánica. Atención: Quítese todas las joyas metálicas, como anillos y relojes, antes de instalar o quitar una tarjeta de red de un chasis con alimentación eléctrica. Utilice circuitos de alimentación dedicados o acondicionadores de alimentación para suministrar energía eléctrica fiable al dispositivo.
Page 59
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Avisos de conformidad de telecomunicaciones Atención: Cuando utilice su equipo telefónico, deberá adoptar las siguientes precauciones de seguridad básicas para reducir el riesgo de incendio, descarga electrónica y lesiones: No utilice este producto en zonas húmedas; por ejemplo, cerca de una bañera, un lavabo o un fregadero, en un sótano húmedo o cerca de una piscina.
Page 60
Appendix B: Translated Safety Statements Avis de sécurité laser Avertissement: Produit laser de classe 1. Avertissement: Ne pas observer directement le rayon laser. Avis de sécurité électrique Avertissement: Pour éviter tout risque d’électrocution, ne pas déposer le capot. L’appareil ne contient aucun composant réparable par l’utilisateur. Il est exposé à des tensions dangereuses et ne doit être ouvert que par un technicien compétent et qualifié.
Page 61
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Avertissement: Respecter les recommandations pour dénuder les fils. Un dénudage excessif risque de présenter des risques pour la sécurité en laissant le fil exposé sur le bornier après l’installation. Avertissement: Lors de l’installation de cet équipement, toujours s’assurer que la connexion de terre de la structure est installée en premier et déconnectée en dernier.
Page 62
Appendix B: Translated Safety Statements Un chemin de câble doit être utilisé pour la connexion à la source d’alimentation si l’unité est alimentée par alimentation c.c. centralisée. Le chemin de câble doit être de type TC agréé UL, intensité nominale de 600 V, 90 °C, trois conducteurs, 14 AWG minimum.
Page 63
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Télécommunications – Avis de conformité Avertissement: Les précautions élémentaires de sécurité doivent être systématiquement respectées en utilisant l’équipement téléphonique pour réduire les risques d’incendie, d’électrocution et d’accident corporel, notamment: Ne pas utiliser ce produit près d’une source d’eau, telle qu’une baignoire, un lavabo, un évier ou un baquet dans un sous-sol humide ou près d’une piscine.
Page 64
Appendix B: Translated Safety Statements Indicazioni sulla sicurezza laser Avvertenza: Prodotto laser Classe 1. Avvertenza: Non fissare il raggio laser. Indicazioni sulla sicurezza elettrica Avvertenza: Per evitare scosse elettriche, non rimuovere la copertura. All'interno non sono presenti componenti utilizzabili dall'utente. Questa unità presenta voltaggi rischiosi e deve essere aperta solo da un tecnico qualificato ed esperto.
Page 65
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Avvertenza: Quando si installa l'apparecchiatura, verificare che il collegamento di messa a terra FG (frame ground) sia installato per primo e disinstallato per ultimo. Avvertenza: Verificare che non sporgano fili di rame dai cavi installati. Se l'installazione viene effettuata correttamente, non vi sono fili di rame scoperti, sporgenti dal blocco terminale.
Page 66
Appendix B: Translated Safety Statements Avvertenza: Rimuovere tutti gli oggetti di metallo, ad esempio anelli e orologi, prima di installare o estrarre una scheda di linea da un chassis acceso. Utilizzare circuiti di alimentazione o alimentatori dedicati per fornire energia elettrica al dispositivo in modo affidabile.
Page 67
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Indicazioni per la conformità con le norme sulle telecomunicazioni Avvertenza: Quando si utilizza l'apparecchiatura telefonica, per ridurre il rischio di incendio, scosse elettriche e danni alle persone, è necessario seguire alcune precauzioni di base per la sicurezza, ad esempio: Non utilizzare il prodotto in prossimità...
Page 68
Appendix B: Translated Safety Statements Лазерная безопасность Внимание: лазерный продукт, класс 1. Внимание: Не смотрите прямо в лазерный луч. Электрическая безопасность Внимание: Для предотвращения электрического шока, не снимайте кожух. Внутри нет частей, подлежащих обслуживанию пользователем. Этот устройство – под опасным напряжением и должно открываться только обученным и квалифицированным...
Page 69
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Внимание: При инсталляции оборудования, убедитесь, что заземление подключается в первую, а отключается в последнюю очередь. Внимание: Проверьте, нет ли на инсталлированных проводков на кабеле. При правильной инсталляции на терминале свободных проводков быть не должно.
Page 70
Appendix B: Translated Safety Statements Для подсоединения источника питания, если установка питается централизованным постоянным током, требуется желобной кабель. Кабель должен быть признанным UL типа и предназначен для 600 В и + 90°C, с тремя кондукторами, минимум 14 AWG (американский калибр). Внимание: Установка...
Page 71
AT-FS750/16 and AT-FS750/24 Fast Ethernet Smart Switches Installation Guide Телекоммуникационное соответствие Внимание: При использовании телефонного оборудования, всегда следует обращать внимания на требования безопасности для снижения риска пожара, поражения током и ранения, в том числе: Не используйте оборудование рядом с водой – например ванной, раковиной или...