Show Power-Inline Counters Interface; Table 25. Show Power-Inline Counters Interface Command - Allied Telesis AT-8100L/8 User Manual

Fast ethernet switches at-8100 series management software command line interface user’s guide alliedware plus version 2.2.5
Hide thumbs Also See for AT-8100L/8:
Table of Contents

Advertisement

SHOW POWER-INLINE COUNTERS INTERFACE

Syntax
show power-inline counters interface
Parameter
port
Specifies a port. You can specify and display more than one port at
a time. Omit this parameter to display all of the ports.
Mode
Privileged Exec mode
Description
Use this command to display the PoE event counters for the ports. An
example is shown in Figure 65.
PoE Counters:
Interface
MPSAbsent Overload Short Invalid Denied
port1.0.4
0
port1.0.5
0
0
port1.0.6
Figure 65. SHOW POWER-INLINE COUNTERS INTERFACE Command
The fields are described in Table 25.

Table 25. SHOW POWER-INLINE COUNTERS INTERFACE Command

Field
Interface
The port number.
Overload
The number of times the PD exceeded the power limit
set with "POWER-INLINE MAX" on page 277.
Short
The number of short circuits the port has experienced.
Invalid
The number of times the port detected an invalid
signature. An invalid signature indicates an open circuit,
a short circuit, or a legacy PD.
AT-8100 Switch Command Line User's Guide
port
0
0
0
0
0
0
0
0
0
Description
0
0
0
285