Description
The Door Box is a self-contained Intercom unit typically used to monitor an entrance door. A visitor at the
door can press the Door Box call button (like a door bell). The Door Box then sends chime tones to all
extensions programmed to receive chimes. To answer the chime, the called extension user just lifts the
handset. This lets the extension user talk to the visitor at the Door Box. The Door Box is convenient to
have at a delivery entrance, for example. It is not necessary to have company personnel monitor the
delivery entrance; they answer the Door Box chimes instead. Any number of system extensions can
receive Door Box chime tones.
Each Door Box has a pair of normally open relay contacts that can connect to an electric door strike. Use
these contacts to remotely control the entrance door. After answering the Door Box chimes, a multiline
terminal user can press the Recall key to activate the Door Box contacts. This in turn releases the
electric strike on the entrance door. The device connected to the Door Box contacts cannot exceed the
contact ratings shown in the following table:
The system can have up to eight Door Boxes. Six chime tones are available.
Conditions
The Door Box Feature Requires a PGD(2)-U10 ADP. A maximum of 56 PGD(2)-U10 ADP
units can be installed in an UNIVERGE SV8100 system. Refer to the UNIVERGE SV8100
System Hardware Manual for more information.
If a PGD(2)-U10 ADP circuit has a Door Box (doorphone) connected, you cannot use that
circuit for External Paging.
Door Boxes can ring multiline, single line, and wireless telephones.
A Door Box cannot ring a virtual extension.
External Call forward by Doorphone can forward Doorphone calls Off-Premise while a user
is away. This feature only works for ISDN lines.

Door Box

Door Box Specifications
Contact Configuration
Maximum Load
Maximum Initial Contact Resistance
Door Box
Normally Open
60mA @30 VDC
10mA @90 VDC
50m Ohms
Issue 8.01
2 - 495