Issue 8.01
Program
Program Name
Number
90-11-02
System Alarm Report – Report
Method
90-11-06
System Alarm Report – SMTP
Host Name
90-11-07
System Alarm Report – SMTP
Host Port Number
90-11-08
System Alarm Report – To Email
Address
90-11-09
System Alarm Report – Reply
Address
90-11-10
System Alarm Report – From
Address
90-11-11
System Alarm Report – DNS
Primary Address
90-11-12
System Alarm Report – DNS
Secondary Address
90-11-13
System Alarm Report –
Customer Name
90-25-01
System Alarm Report CC Mail
Setup – CC Mail Address
90-50-01
System Alarm Display Setup –
System Alarm Display
Telephone
2 - 38
Description/Comments
When Alarm Reports are to be
emailed, set this option to 1. This
program has higher priority than
Program 90-12-06.
When Alarm Reports are to be
emailed, set the SMTP name (for
example, smtp.yourisp.com).
Contact your ISP (Internet Service
Provider) for the correct entry if
needed.
When Alarm Reports are to be
emailed, set the SMTP host port
number. Contact your ISP
(internet service provider) for the
correct entry if needed.
When Alarm Reports are to be
emailed, set this email address to
which the report should be sent.
When Alarm Reports are to be
emailed, set the email address
where replies should be emailed.
When Alarm Reports are to be
emailed, set this email address for
the station sending the report.
When Alarm Reports are to be
emailed, set the DNS primary
address.
When Alarm Reports are to be
emailed, set the DNS secondary
address.
When Alarm Reports are to be
emailed, enter a name to identify
the particular system.
Define the mail address to receive
the system alarm report CC Mail
setup.
Define the extension number that
Alarm reports are displayed on.
UNIVERGE SV8100
Assigned Data
1
0 = No Report
1 = Email Address
(default = 0)
Up to 255 characters
(default not assigned)
0~65535
(default = 25)
Up to 255 characters
(default not assigned)
Up to 255 characters
(default not assigned)
Up to 255 characters
(default not assigned)
0.0.0.0~
255.255.255.255
(default = 0.0.0.0)
0.0.0.0~
255.255.255.255
(default = 0.0.0.0)
Up to 255 characters
(default not assigned)
Up to 255 characters
(default not assigned)
Up to eight digits
(default not assigned)
Alarm Reports
Level
2
3