NEC Univerge SV8100 Features And Specifications Manual page 132

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 8.01
Program
Program Name
Number
80-04-05
Call Progress Tone Detector
Setup – Pulse Count
80-04-06
Call Progress Tone Detector
Setup – ON Minimum Time
80-04-07
Call Progress Tone Detector
Setup – ON Maximum Time
80-04-08
Call Progress Tone Detector
Setup – OFF Minimum Time
80-04-09
Call Progress Tone Detector
Setup – OFF Maximum Time
2 - 104
Description/Comments
Set the Pulse Count.
Set the minimum On time.
Set the maximum On time.
Set the minimum Off time.
Set the maximum Off time.
UNIVERGE SV8100
Assigned Data
1
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255 (30+30-
7680ms)
default:
Type 1 (DT) – 9
(300ms)
Type 2 (BT) – 12
(300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 20
(630ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
1~255 (30+30-
7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 12
(390ms)
Type 3 (RBT) – 83
(2520ms)
Type 4, Type 5 – 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 20
(630ms)
Type 3 (RBT) – 115
(3480ms)
Type 4, Type 5 – 0
Automatic Release
Level
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents