Issue 8.01
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
20-01-06
System Options – Alarm
Duration
Operation
To set the alarm:
1.
At the multiline terminal, press Speaker.
- OR -
At the single line telephone, lift the handset.
2.
Dial 727.
3.
Dial alarm type (1 or 2).
Alarm 1 sounds only once. Alarm 2 sounds each day at the preset time.
4.
Dial the alarm time (24-hour clock).
For example, for 1:15 PM dial 1315.
A confirmation tone is heard if the alarm has been set. If the alarm was not set, an error tone is heard instead.
5.
At the multiline terminal, press Speaker to hang up.
- OR -
At the single line telephone, hang up.
2 - 26
Description/Comments
Set the duration of the Alarm
signal.
UNIVERGE SV8100
Assigned Data
1
0~64800 seconds
(default = 30)
Level
2
3
Alarm