NEC Univerge SV8100 Features And Specifications Manual page 641

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
81-10-07
COT Initial Data Setup –
Hookflash Time Selection 1
81-10-08
COT Initial Data Setup –
Hookflash Time Selection 2
Flash
Description/Comments
Set the Flash duration
(16~4080ms) for analog trunk
CD-4COTB circuits in Program
81-10-07.
Set the open loop disconnect
duration (16~4080ms) for analog
trunk CD-4COTB circuits Program
81-10-08.
Assigned Data
1
0 = 20ms
1 = 40ms
2 = 60ms
3 = 80ms
4 = 100ms
5 = 140ms
6 = 160ms
7 = 200ms
8 = 400ms
9 = 600ms
10 = 800ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 9 (600ms)]
0 = 20ms
1 = 40ms
2 = 60ms
3 = 80ms
4 = 100ms
5 = 140ms
6 = 160ms
7 = 200ms
8 = 400ms
9 = 600ms
10 = 800ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 14 (3.0
seconds)]
Issue 8.01