NEC Univerge SV8100 Features And Specifications Manual page 130

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 8.01
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
14-02-09
Analog Trunk Data Setup – Busy
Tone Detection
14-02-14
Analog Trunk Data Setup – Loop
Start/Ground Start
80-04-01
Call Progress Tone Detector
Setup – Detection Level
2 - 102
Description/Comments
Enable/Disable Busy Tone
Detection.
Identify the analog trunk as either
loop or ground start.
Set the Detection Level.
UNIVERGE SV8100
Assigned Data
1
0 = Disable (No)
1 = Enable (Yes)
(default = 0)
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
(default = 0)
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
Automatic Release
Level
2
3

Hide quick links: