Issue 8.01
Program
Program Name
Number
10-05-01
General Purpose Relay Setup –
Slot No. Physical Port of DLCA
Sensor Circuit No.
11-12-36
Service Code Access (for
Service Access) – Door Box
Access
15-07-01
Programmable Function Keys
32-01-01
Door Box Timers – Door Box
Answer Time
32-01-02
Door Box Timers – Door Lock
Cancel Time
32-01-03
Door Box Timers – Off-Premise
Call Forward by Door Box
Disconnect Timer
32-02-01
Door Box Ring Assignments
2 - 498
Description/Comments
Define which Relay circuits (5~8)
on a PGD(2)-U10 ADP Adapter
are used for General Purpose
Relay.
If the service code for Doorphone
Access is not acceptable, change
it here.
Assign a function key for External
Call Forward by Doorphone (Code
54).
Set the time a user has to answer
the Door Box chimes.
Set the time the Door Box strike
stays open when the single line
telephone user hookflashes or a
multiline terminal user presses
Recall.
Define the conversation time for
an Off-Premise Call Forward by
Door Box call. When this timer
expires, the caller hears busy tone
for 3 seconds (fixed time), and the
call is then disconnected.
Determine which Door Box should
ring which extension by entering
the extension number. Each Door
Box can be programmed to ring up
to 32 extensions and an extension
can be programmed to ring for
multiple Door Boxes.
UNIVERGE SV8100
Assigned Data
1
Slot No: 0~24
DCLA Port: 0~16
Relay No: 0, 5~8
After each entry,
pressing the
Transfer Key
advances to the
next entry.
(default = 0 - 0 - 0)
MLT, SLT
(default = 702)
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
0~64800 (seconds)
(default = 30)
0~64800 (seconds)
(default = 10)
0~64800 (seconds)
(default = 60)
Maximum eight digits
(default not assigned)
Level
2
3
Door Box