Program
Program Name
Number
12-01-02
Night Mode Function Setup –
Automatic Night Mode Switching
12-02-01
Automatic Night Service
Patterns –Start Time
12-02-02
Automatic Night Service
Patterns –End Time
12-02-03
Automatic Night Service
Patterns –Operation Mode
Automatic Route Selection
Description/Comments
According to a preset schedule,
Enable (1)/Disable (0) Automatic
Night Service for the system.
Make sure to set the Service
Patterns in Program 12-02-01,
Program 12-02-02 and Program
12-02-03.
Define the daily pattern of the
Automatic Mode Switching. Each
Mode Group has 10 patterns.
These patterns are used in
Programs 12-03 and 12-04. The
daily pattern consists of 20 timer
settings.
This option defines the starting
time.
Define the daily pattern of the
Automatic Mode Switching. Each
Mode Group has 10 patterns.
These patterns are used in
Programs 12-03 and 12-04. The
daily pattern consists of 20 timer
settings.
This option defines the ending
time.
Define the daily pattern of the
Automatic Mode Switching. Each
Mode Group has 10 patterns.
These patterns are used in
Programs 12-03 and 12-04. The
daily pattern consists of 20 timer
settings.
This option defines the operation
mode that the system should be in
during each time number.
Assigned Data
1
0 = Off
1 = On
(default = 0)
0000~2359
Refer to the SV8100
Programming Manual
for defaults.
0000~2359
Refer to the SV8100
Programming Manual
for defaults.
1~8
(default = 1 or 2
depending on time
pattern and time
number.)
Issue 8.01