1000BaseSX
1000BaseLX
1000BaseLHA
1000BaseLHB
a.
The TIA 568 building wiring standard specifies 160/500 MHz*km MMF (Multi-mode
Fiber).
b.
The international ISO/IEC 11801 building wiring standard specifies 200/500
MHz*km MMF.
c.
The ANSI Fibre Channel specification specifies 500/500 MHz*km 50 micron MMF
and 500/500 MHz*km fiber has been proposed for addition to ISO/IEC 11801.
NOTE: Cable installation and network configuration will affect overall transmission capability. The numbers
provided above represent the accepted recommendations of the various standards. For network-specific
recommendations, consult your local Foundry reseller or system engineer.
December 2000
Table 2.3: Cable length summary table
Fiber Type
Core
Diameter
(microns)
MMF
62.5
MMF
62.5
MMF
50
MMF
50
MMF
62.5
MMF
50
MMF
50
SMF
9
SMF
9
SMF
9
Installing a Foundry Layer 2 Switch or Layer 3 Switch
Modal
Minimum
Bandwidth
Range
(MHz*km)
(meters)
160
2 – 200
200
2 – 275
400
2 – 500
500
2 – 550
500
2 – 550
400
2 – 550
500
2 – 550
n/a
2 – 5000
n/a
2 – 70000
(70km)
n/a
2 – 150000
(150km)
a
b
c
2 - 23