Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 50.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees
USING THE WEB MANAGEMENT INTERFACE
1.
Log on to the device using a valid user name and password for read-write access. The System configuration
dialog is displayed.
2.
Click on the plus sign next to Monitor in the tree view to display the Monitor options.
3.
Select the System Log link to display the system log.
Changing Temperature Warning and Shutdown Levels
The default warning temperature is 45.0 C degrees. The default shutdown temperature is 55.0 C degrees. You
can change the warning and shutdown temperatures using the following commands. The valid range for each
value is 0 – 125 C degrees.
NOTE: You cannot set the warning temperature to a value higher than the shutdown temperature.
USING THE CLI
To change the temperature at which the module sends a warning, enter a command such as the following at the
Privileged EXEC level of the CLI:
BigIron# temperature warning 47
Syntax: temperature warning <value>
The <value> can be 0 – 125.
To change the shutdown temperature, enter a command such as the following at Privileged EXEC level of the CLI:
BigIron# temperature shutdown 57
Syntax: temperature shutdown <value>
The <value> can be 0 – 125.
USING THE WEB MANAGEMENT INTERFACE
1.
Log on to the device using a valid user name and password for read-write access. The System configuration
dialog is displayed.
2.
Select the Advance link to display the following panel.
December 2000
Using Redundant Management Modules
5 - 35