Software
You can display status information for a POS module using either of the following methods.
NOTE:
Slots on a 4-slot chassis are numbered 1 – 4, from top to bottom.
Slots on an 8-slot chassis are numbered 1 – 4, from top to bottom.
Slots on a 15-slot chassis are numbered 1 – 15, from left to right.
USING THE CLI
To display the status of a POS module using the CLI, enter the following command at any CLI level:
BigIron> show module
Module
S1: B0GMR Management Module
S2: BI POS 622M Module
S3: B24E Copper Switch Module
S4: B8G Fiber Switch Module
Syntax: show module
NOTE: The module descriptions do not distinguish between SX and LX ports.
The Status column shows the module status. A POS module can have one of the following statuses:
FAILED – This status indicates that the host module failed to come up.
OK – This status indicates that the module came up and is operating normally.
NOTE: Management modules have different status values.
USING THE WEB MANAGEMENT INTERFACE
1.
Select the System link to display the System configuration sheet, if not already displayed.
2.
Select the Module link to display the Module panel. The Status column shows the module status. A POS
module can have one of the following statuses:
FAILED – This status indicates that the host module failed to come up.
OK – This status indicates that the module came up and is operating normally.
Displaying Interface Parameters
To display the current settings for the POS interface parameters, use the following method.
USING THE CLI
To display interface information using the CLI, enter the following command at any CLI level:
BigIron> show interface brief slot 2
Port Link State
2/1
up
2/2
up
Syntax: show interface brief [pos <portnum>] | [slot <slotnum>]
This command shows information for all the ports in the chassis. For simplicity, the example and syntax above
show only the information relevant to POS ports.
December 2000
Encap Clock Loop Speed
ppp
int
none 622
ppp
int
none 155
Using Packet Over SONET (POS) Modules
Status
Ports Starting MAC
ACTIVE
0
OK
2
00e0.5281.eb20
OK
24
00e0.5281.eb40
OK
8
00e0.5281.eb60
mtu
frame
scram
1200
sonet
no
1500
sonet
no
crc c2 j0 h1
16
cf cc 00
16
cf cc 00
6 - 23