F.3.3.3 (Select:) Odu Menu Branches; F.3.3.3.1 Odu: Buc:pwrsupply+Ref (Power Supply And Reference); F.3.3.3.1.1 Odu: Buc:pwrsupply+Ref  Psu-And-10Mhz Parameters - Comtech EF Data CDM-625 Installation And Operation Manual

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625:
Table of Contents

Advertisement

CDM-625 Advanced Satellite Modem
Appendix F
F.3.3.3
(SELECT:) ODU Menu Branches
ODU: BUC:PwrSupply+Ref
Use the
◄ ►
arrow keys to select BUC:PwrSupply+Ref, LNB:PwrSupply+Ref, or FSK-control, and
then press ENTER:
ODU Menu Branch
BUC:PwrSupply+Ref
LNB:PwrSupply+Ref
FSK-control
F.3.3.3.1
ODU: BUC:PwrSupply+Ref (Power Supply and Reference)
BUC control/monitor (non-FSK):
PSU-and-10MHz
The modem provides DC power and a 10MHz reference that may be used by a BUC. Use the
arrow keys to select PSU-and-10MHz, LO-Freq, or PSUmonitor, and then press ENTER.
F.3.3.3.1.1 ODU: BUC:PwrSupply+Ref  PSU-and-10MHz Parameters
BUC supply=N/I
Alarm limits, from 0.0 to 2.0 amps ()
◄ ►
Use the
arrow keys to select BUC Supply, 10MHz-ref, or Alarm Limits, and then use the
arrow keys to select a setting:
▲▼
Selection
BUC supply
10MHz-ref
Alarm Limits
Press ENTER when done.
LNB:PwrSupply+Ref
Sect.
Nested Menu Function
F.3.3.3.1
Provides menus to enter a T x LO frequency, and t o control a 10 MHz
reference and for Power supply control and alarm limits.
F.3.3.3.2
Provides menus to enter an Rx LO frequency, and to control a 10MHz
reference and for Power supply control and alarm limits.
F.3.3.3.3
(Frequency S hift K eying c ontrol) P rovides m enus t o m onitor and
control CSAT-5060 O R KST-2000A/B or B UC settings, and LPOD
settings v ia Advanced F SK. T he appear ance of , and t he f unctional
selections av ailable f rom t his ne sted m enu ar e dependent on t he T x
frequency employed – 70/140 versus L-Band.
LO-freq
10MHz-ref:Off (Off,On)
Setting
Indicates installation state, e.g., N/I =- Not Installed.
Set the 10MHz Reference as Off or On.
A BUC will not transmit without a 10MHz reference.
Use the ◄ ►arrow keys to select a digit to edit, and then use the ▲▼ arrow keys to
change that digit. Valid range, in Amps, is 0.0 to 4.0.
FSK-control ()
PSUmonitor ()
F–10
Revision 13
MN-CDM625

Advertisement

Table of Contents
loading

Table of Contents