CDM-625 Advanced Satellite Modem
Appendix F
Selection
Fault-Logic
LNA
Fault-Logic
Cal
Press ENTER when done.
ODU: FSK-control KST Information
F.3.3.3.3.3.1.4
KST Info:
These read-only screens provide the ODU's current configuration information without risking
inadvertent changes.
◄ ►
Use the
arrow keys to select Model, Tx+Rx-Param, Misc, or Numbers, and then press
ENTER.
Once any KST Info screen has been viewed, press ENTER or CLEAR to return to the previous
menu.
ODU: FSK-control KST Information Model
F.3.3.3.3.3.1.5
MODEL:
This screen displays the KST and HPA model numbers.
ODU: FSK-control KST Information Tx+Rx-Param
F.3.3.3.3.3.1.6
Info: Tx:Off
This screen displays the Tx and Rx states, Frequencies, and Attenuation, and the reference.
Setting
This controls whether or not a HPA fault is indicated on t he Fault status, and ac tivates
the Summary Fault Relay. Select Summary or No-Summary.
(LNA power enable) Select Off or On.
This controls whether or not a L NA fault is indicated on the Fault status, and l activates
the Summary Fault Relay. Select Summary or No-Summary.
To calibrate, select YES and press ENTER. Calibration allows the system to determine
nominal LNB or LNB power consumption, performed at initial installation only. (Default is
NO.)
Model
Misc
KST-2000B
HPA:
CEFD-SSPA
13955MHz
Rx:
11950MHz
Tx+Rx-Param
Numbers
10dB
20dB
Ref:087
F–24
Revision 13
MN-CDM625
()