DGS-3120-24TC:admin#show snmp traps
Command: show snmp traps
SNMP Traps
Authenticate Trap
Linkchange Traps
Coldstart Traps
Warmstart Traps
DGS-3120-24TC:admin#

72-34 config rmon trap

Description
This command is used to configure the trap state for RMON events.
Format
config rmon trap {rising_alarm [enable | disable] | falling_alarm [enable | disable]} (1)
Parameters
rising_alarm - (Optional) Specify the trap state for rising alarm. The default state is enabled.
enable - Specify that the rising alarm function will be enabled.
disable - Specify that the rising alarm function will be disabled.
falling_alarm - (Optional) Specify the trap state for falling alarm. The default state is enabled.
enable - Specify that the falling alarm function will be enabled.
disable - Specify that the falling alarm function will be disabled.
Restrictions
Only Administrator level can issue this command.
Example
To configure the trap state for RMON events:
DGS-3120-24TC:admin# config rmon trap rising_alarm disable
Command: config rmon trap rising_alarm disable
Success.
DGS-3120-24TC:admin#

72-35 show rmon

Description
This command is used to display the RMON related setting.
DGS-3120 Series Managed Switch CLI Reference Guide
: Enabled
: Enabled
: Enabled
: Enabled
: Enabled