Sflow Command List (Ei Mode Only) - D-Link DGS-3120-48PC Reference Manual

Layer 2 managed stackable gigabit switch
Hide thumbs Also See for DGS-3120-48PC:
Table of Contents

Advertisement

xStack
Chapter 69
create sflow flow_sampler ports [<portlist> | all] analyzer_server_id <value 1-4> {rate <value 0-
65535> | maxheadersize <value 18-256>}
config sflow flow_sampler ports [<portlist> | all] {rate <value 0-65535> | maxheadersize <value
18-256>}
delete sflow flow_sampler ports [<portlist> | all]
create sflow counter_poller ports [<portlist> | all] analyzer_server_id <value 1-4> {interval
[disable | <sec 20-120>]}
config sflow counter_poller ports [<portlist> | all] interval [disable | <sec 20-120>]
delete sflow counter_poller ports [<portlist> | all]
create sflow analyzer_server <value 1-4> owner <name 16> {timeout [<sec 1-2000000> |
infinite] | collectoraddress <ipaddr> | collectorport <udp_port_number 1-65535> |
maxdatagramsize <value 300-1400>}
config sflow analyzer_server <value 1-4> {timeout [<sec 1-2000000> | infinite] | collectoraddress
<ipaddr> | collectorport <udp_port_number 1-65535> | maxdatagramsize <value 300-1400>}
delete sflow analyzer_server <value 1-4>
enable sflow
disable sflow
show sflow
show sflow flow_sampler
show sflow counter_poller
show sflow analyzer_server
69-1
create sflow flow_sampler
Description
This command is used to create the sFlow flow sampler. By configuring the sampling function for a
port, a sample packet received by this port will be encapsulated and forwarded to analyzer server
at the specified interval.
Format
create sflow flow_sampler ports [<portlist> | all] analyzer_server_id <value 1-4> {rate <value
0-65535> | maxheadersize <value 18-256>}
Parameters
ports - Specify the list of ports to be configured.
<portlist> - Enter the list of ports that will be used for this configuration here.
all - Specify all ports on the Switch.
analyzer_server_id - Specify the ID of a server analyzer where the packet will be forwarded.
<value 1-4> - Enter the analyzer server ID here. This value must be between 1 and 4.
rate - (Optional) The sampling rate for packet Rx sampling. The configured rate value multiplied
by x is the actual rate, where the x is project dependent with the default value 256. If set to 0,
the sampler is disabled. If the rate is not specified, its default value is 0.
<value 0-65535> - Enter the sampling rate value here. This value must be between 0 and
65535.
maxheadersize - (Optional) The maximum number of leading bytes in the packet which has
®
DGS-3120 Series Managed Switch CLI Reference Guide
sFlow Command List (EI
Mode Only)
627

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xstack dgs-3120 series

Table of Contents