vlanid - Specify a range of VLANs to be configured.
<vlanid_list> - Enter the VLAN ID list here.
<value 1-1000> - Configure the rate of the IGMP control packet that the Switch can process on a
specific port/VLAN. The rate is specified in packets per second. The packets that exceed the
limit will be dropped.
no_limit - Configure the rate of the IGMP control packet to be unlimited that the Switch can
process on a specific port/VLAN. The rate is specified in packets per second. The packets that
exceed the limit will be dropped. The default setting is no_limit.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure the IGMP snooping per port rate_limit:
DGS-3120-24TC:admin#config igmp_snooping rate_limit ports 1:1 100
Command: config igmp_snooping rate_limit ports 1:1 100
Success.
DGS-3120-24TC:admin#
33-3
config igmp_snooping querier
Description
This command is used to configure the time in seconds between general query transmissions, the
maximum time in seconds to wait for reports from members, and the permitted packet loss that
guarantees IGMP snooping.
Format
config igmp_snooping querier [vlan_name <vlan_name 32> | vlanid <vlanid_list> | all]
{query_interval <sec 1-65535> | max_response_time <sec 1-25> | robustness_variable
<value 1-7> | last_member_query_interval <sec 1-25> | state [enable | disable] | version
<value 1-3>}(1)
Parameters
vlan_name - Specify the name of the VLAN for which IGMP snooping querier is to be configured.
<vlan_name 32> - Enter the VLAN name here. The VLAN name can be up to 32 characters
long.
vlanid - Specify the VLAN ID for which IGMP snooping querier is to be configured.
<vlanid_list> - Enter the VLAN ID list here.
all - Specify all VLANs for which IGMP snooping querier is to be configured.
query_interval - (Optional) Specify the amount of time in seconds between general query
transmissions. The default setting is 125 seconds.
<sec 1-65535> - Enter the query interval value here. This value must between between 1 and
65535 seconds.
max_reponse_time - (Optional) Specify the maximum time in seconds to wait for reports from
members. The default setting is 10 seconds.
<sec 1-25> - Enter the maximum response time value here. This value must be between 1
DGS-3120 Series Managed Switch CLI Reference Guide