Switchstatuspolicyset; Contributor Value And Status - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS Commands

switchStatusPolicySet

Set the policy parameters that determine the overall switch status.
Synopsis
switchStatusPolicySet
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to set the policy parameters for calculating the overall status of
the switch enclosure. The policy parameter values determine how many failed or
faulty units of each contributor are allowed before triggering a status change in the
switch from HEALTHY to MARGINAL or DOWN.
The command will print the current parameters in a three column table format.
The first column specifies the contributor; the second column specifies the
minimum number that contributes to the DOWN/FAILED status; the third column
specifies the minimum number that contributes to the MARGINAL/WARNING
status. This command then prompts the user to change the values for each policy
parameter. The default values for the policy parameters are as follows:
Table 16: Contributor Value and Status
Contributor
FaultyPorts
MissingSFPs
PowerSupplies
828
Default Value for DOWN
2
0
2 (V3.1.x only)
2 in the StorageWorks 2 Gb
SAN switch (V4.1.x only)
3 in the StorageWorks Core
switch (V4.1.x only)
Default Value
for MARGINAL
1
0
1
Fabric OS Version 3.1.x/4.1.x Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 3.1Storageworks fabric os 4.1

Table of Contents