HP StorageWorks MSA 2/8 - SAN Switch Reference Manual page 93

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

To test the ASIC central memory in V4.1.x:
switch:admin> centralmemorytest -ports 1/0-1/15
Running centralmemorytest ............ passed.
Test Complete: "centralmemorytest" Pass 1 of 1
Duration 0 hr, 0 min & 5 sec (0:0:5:412).
passed.
Errors
When this command detects failures, each subtest may report one or more of the
following error messages:
Fabric OS Version 3.1.x/4.1.x Reference Guide
For V3.1.x:
Subtest 1
1) DIAG-CMBISRF
Subtest 2
1) DIAG-LCMTO
2) DIAG-LCMRS
3) DIAG-LCMEM
Subtest 3
1) DIAG-CMNOBUF
2) DIAG-LCMTO
3) DIAG-LCMRS
4) DIAG-LCMEMTX
Subtest 4
1) DIAG-TIMEOUT
2) DIAG-BADINT
3) DIAG-CMERRTYPE
4) DIAG-CMERRPTN
Subtest 5
1) DIAG-TIMEOUT
2) DIAG-BADINT
3) DIAG-CMERRTYPE
4) DIAG-CMERRPTN
Subtest 6
1) DIAG-TIMEOUT
2) DIAG-BADINT
3) DIAG-CMERRTYPE
4) DIAG-CMERRPTN
centralMemoryTest
93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 3.1Storageworks fabric os 4.1

Table of Contents