diagsetcycle

Set diagnostic script parameters.
Synopsis
diagSetCycle script [-show | -default | [-keyword
value]]
Availability
Admin
Release
V4.1.x
Description
This command provides interactive way of updating diagnostic command
parameters. With only script specified, it will display all configuration variables
used by the specified script and go into an interactive session. Using the full
stretched option parameters, variables can be updated non interactively too.
In interactive mode, the current value, default value, and description of purpose of
the variable are displayed for each variable. If no new value is specified, then the
current value is left unchanged. If a new value is entered, then its value is updated,
and stored in the configuration database for that blade type. It does not require a
reboot to take effect.
Operands
This command has the following operands:
script
-show
-default
Fabric OS Version 3.1.x/4.1.x Reference Guide
Specify which script's parameters to edit.
Specify this operand to display the parameters for a
diagnostic script specified by script.
Specify this operand to set the script parameters to
default values.