To test cascading ISL links (V4.1.x example):
switch:admin> > spinfab -ports 1/0 - 1/2
spinfab running...
spinfab: Completed 11 megs, status:
port 0 test status: 0x00000000 --
port 1 test status: 0x00000000 --
port 2 test status: 0x00000000 --
Test Complete: "spinfab" Pass 10 of 10
Duration 0 hr, 0 min & 41 sec (0:0:41:877).
passed.
switch:admin>
Errors
When it detects failures, the test may report one or more of the following error
messages:
Fabric OS Version 3.1.x/4.1.x Reference Guide
For V3.1.x:
DIAG-INIT
DIAG-PORTDIED
DIAG-XMIT
DIAG-PORTSTOPPED
DIAG-ERRSTATS
DIAG-ERRSTAT
For V4.1.x:
DATA
ERR_STAT
ERR_STATS
ERR_STATS_2LONG
ERR_STATS_BADEOF
ERR_STATS_BADOS
ERR_STATS_C3DISC
ERR_STATS_CRC
ERR_STATS_ENCIN
ERR_STATS_ENCOUT
ERR_STATS_TRUNC
ERR_STAT_2LONG
ERR_STAT_BADEOF
ERR_STAT_BADOS
ERR_STAT_C3DISC
ERR_STAT_CRC
ERR_STAT_ENCIN
ERR_STAT_ENCOUT
ERR_STAT_TRUNC
FINISH_MSG_ERR
INIT
MBUF_STATE_ERR
NO_SEGMENT
PORT_ABSENT